AccuRad™ PRD | Military Radiation Detector for Security and Emergency Forces
Your shopping cart is empty!
Product Description
AccuRad PRD is a discreet, robust and intuitive gamma radiation detector, developed to meet the needs of security forces, emergency teams and civilians without specialised technical training, and is suitable for both civilian and military use. Designed for critical scenarios and routine operations, it allows for the quick and accurate identification of nuclear and radioactive materials, ensuring reliable measurements at both low and high dose rates. The result of close collaboration with professionals in the field, this is the first device of its kind to combine professional performance with civilian-friendly use, ensuring maximum effectiveness in civilian and military contexts, regardless of the user's experience.
Resistant and reliable, the AccuRad PRD features an impact-proof design, prepared for repeated use in adverse conditions, offering professionals and civilians a reliable and intuitive solution in situations of radiological risk.

Features:
- Rugged and durable: Impact-resistant design for repeated use in harsh conditions.
- Discreet and hands-free: Low-profile with top display for easy, at-a-glance reading.
- Waterproof: Suitable for tough environments, including firefighting.
- Directional accuracy: Built-in directionality to locate hot spots in crowded environments.
- Long battery life: 900 hours of field use with easily replaceable AA batteries.
- High-energy photon measurement: Complies with IEC 60846-1 standard for use near nuclear facilities.
- Low dose rate measurement: Ensures public safety by establishing safe zones.
Be alerted only to genuine threats. The AccuRad PRD uses innovative Variable Background Suppression (VBS) technology, allowing it to function effectively in diverse background environments. It only alarms for genuine threats or dangers.
Get accurate radiation exposure readings. The AccuRad PRD provides precise tissue equivalent dose measurements and dose alarms for radiological events, leveraging Mirion’s extensive radiation safety expertise.
Analyze data in real-time. The companion app offers real-time data visualization and retransmission capabilities, enhancing situational awareness across multiple PRDs and other detectors. Compatible with platforms such as RadResponder, Sigma, and SpirView Mobile™.
The AccuRad PRD is purpose-built to withstand the realities of field operations.
Specifications:
Physical Characteristics:
Weight: 200g (7oz), including clip
Size: 108 x 61 x 36 mm (4.25 x 2.4 x 1.4 in.) without clip
Batteries:
- Two AA batteries for over 900 hours of continuous operation
- Tool-free battery cover
Environmental:
Protection rating: IP67 (dust and 1m water immersion)
Temperature: -25°C to 60°C
Drop: 1.5m (4.9 ft) onto concrete
- Innovative dual-material rugged construction
- Reinforced, replaceable clip
User Interface:
- Operating modes: Dose or count rate, search with trend or radar, 0-9 display indicator
- Display: Top-mounted for hands-free viewing and alarm assessment
- Inverted contrast option
Languages: Arabic, Chinese, English, French, German, Italian, Japanese, Korean, Polish, Spanish
- Buttons and navigation: Intuitive, training-free use, glove-compatible, suitable for low-visibility environments (gas mask)
Alarms:
- Vibration
- Visual LED
- Audible: 85 dB(A) at 30 cm (11.8 in.)
Radiological Performance:
Detectors:
- CsI (TI) scintillation detector with temperature-compensated SiPM for interdiction and public safety missions
- Silicon diode for integrated high and low dose and dose rate measurements for health and safety in emergency response
Performance:
- Alarms at 50 μrem/h (0.5 μSv/h) within two seconds
- VBS: Authenticates true alarms in variable backgrounds
- Energy range: Detects all radionuclides of interest from 25 KeV to 10 MeV
- Dose rate response: ±25% from 55 KeV to 10 MeV
Dose and Dose Rate Ranges (rem):
- Low dose rate (CsI): 1 μrem/h to 100 mrem/h (Cs-137). Min displayed: 0.1 μrem/h
- High dose rate (Diode): 100 mrem/h to 1000 rem/h (Cs-137)
- Dose range: 10 μrem to 1000 rem (Cs-137). Min displayed: 1 μrem
- Linearity and dose rate range: ±10% from 10 μrem/h to 1000 rem/h
Dose and Dose Rate Ranges (Sv):
- Low dose rate (CsI): 0.01 μSv/h to 1 mSv/h (Cs-137). Min displayed: 0.001 μSv/h
- High dose rate (Diode): 1 mSv/h to 10 Sv/h (Cs-137)
- Dose range: 10 μSv to 10 Sv (min displayed: 1 μSv)
- Linearity and dose rate range: ±10% from 0.1 μSv/h to 10 Sv/h
- Linearity and dose range: ±10% from 0.1 μSv to 10 Sv
Connectivity:
- Bluetooth® Low Energy with Near Field Communications (NFC) for smartphone pairing
- USB Type-C for headset, maintenance, and charging
App Features:
- Remote viewing, settings, history and log access, batch configuration, and updates (Android, iOS, Windows 10)
- Reachback/streaming: e-mail, SMS, SpirVIEW Mobile, RadResponder (Android and iOS)
- Learning section with instructional videos and documentation (Android and iOS)
Included and Related Products:
Included:
- AccuRad PRD, AA alkaline batteries, quick start guide, spare clip
Training modules:
- Radiation safety for law enforcement, firefighters, and other responders
Simulators:
- AccuRad Simulator Kit-1: ref ACCURAD-SIMKIT1
- AccuRad Simulator Kit-4: ref ACCURAD-SIMKIT4
- AccuRad Simulator Kit-6: ref ACCURAD-SIMKIT6
Accessories & Spare Parts:
- 2xAA Ni-Mh battery pack: ref. 16891.
- Complete vehicle mount: ref 7093393
- Rugged cases for 1 or 25 units
- USB-C cables: ref 7094665 or ACO005104
- USB to USB-C headset: ref NOM005479
- Test tool with Cs-137 source: ref 7095627 (US only)
- Spare clip, battery separator, battery cover, screen protector

Standards and Ordering Information:
AccuRad PRDs comply with:
- ANSI N42.32-2016
- IEC 62401:2017
- IEC 60846-1:2009
- IEC 60846-2:2015
Available Versions:
AccuRad PRD Hp(10): ANSI N42.32-2016, ANSI N42.20-2003, ANSI N42.17A
- Ref: ACCURAD (Americas) or NOM005331 (other countries)
AccuRad PRD H(10): IEC 62401:2017, IEC 60846-1:2009, IEC 60846-2:2015
- Ref: NOM008516
Total estimated delivery time
After confirming your order on Portugal Bunkers & Shelters, you will receive a confirmation email with all product information, prices and taxes.
After we submit your request, you will receive an email again confirming that your order has been sent.
The total time required to receive an order is as follows:

Total shipping time is calculated from the time your order is placed to the time it is shipped. Total delivery time is divided into processing time and shipping time.
Processing Time: The time required to analyse your order and prepare the products for shipment from our warehouse. This includes, in some cases, the production or customisation of products.
Packaging time: The time required to package the products. This includes the quality control checks when products were customised.
Delivery Time: The time it takes for the product to ship from our warehouse to your shipping address.
Delivery time may be conditioned by the address you enter in your purchase.
If you require further information, please contact our customer service.
We would be happy to support you with your purchase.
English
Português